Aegis AEGIS 1000 Instalační manuál

Procházejte online nebo si stáhněte Instalační manuál pro Bezpečnostní systémy pro řízení přístupu Aegis AEGIS 1000. Aegis AEGIS 1000 Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Installation Manual

AEGIS 1000 Installation Manual Part No. AEG1000-IMAN Document Number 21I00-

Strany 2

Page 10 PLATEZONEZONEPLATEZONEZONEBOTTOMBOTTOMSYSTEM SENSORMODEL 2100TSMODEL 2100TSSYSTEM SENSORWHEN Z8 USEDFOR SMOKE, J9MUST BE INTHIS POSITIONBE

Strany 3 - CONTENTS

Page 11 ZONEZONE+12VGNDPLATEZONEGND+12VZONEBOTTOMMODEL A77-716BEOL POWERSUPERVISIONRELAYZONEPOWERVIOLETVIOLETREDBLACKYELLOWBLACKGREENREDMODEL 1503A

Strany 4 - SMOKE DETECTOR INSTALLATION

Page 12 TELEPHONE CONNECTIONS 1. If an RJ31X jack has been supplied by the telephone company, it is probably wired correctly and the controller ca

Strany 5 - INSTALLATION

Page 13 GREENREDBROWNGRAYBEND TAB UP IFNECESSARY TOENSURE TIGHT FITGREEN(+)RED(-)RED(-)GREEN(+)RJ11HOUSEPHONEJACK(S)TO ALL HOUSETELEPHONES,KSU, ANDCO

Strany 6 - FIGURE 1 – CONTROLLER HOOKUP

Page LCD CONSOLE HOOKUP 1. 4 LCD Consoles (Models 11A00- -6, 7, and - Use 4 conductor 22- be divided by the total number of consoles at the en

Strany 7

Page 15 LANGUAGE This option is to display the 'console setup' text on the LCD display in English, French, Italian, or Spanish. Select

Strany 8

Page 16 SUPPLIED CABLEBOTTOM PLATE FIGURE 6 - CONSOLE CONNECTIONS

Strany 9 - ABOUT FIRE ZONES

Page 17 BELL OUTPUT The Bell Output provides 12VDC to power bells, piezo sirens, self-contained sirens, and siren drivers (do not connect speakers

Strany 10 - Page 10

Page 18 CONTROLLER OUTPUTS The Aegis 1000 provides 2 programmable hardwired voltage outputs on the controller and 8 voltage outputs on the Expansi

Strany 11 - Page 11

Page 19 REMOTE ARM/DISARM SWITCH 1. If desired, a remote keyswitch, keypad, or hidden arm/disarm toggle can be connected to the system. The devic

Strany 12 - TELEPHONE CONNECTIONS

Copyright © 2002 HAI All Rights Reserved Home Systems Plus www.aegishome.com

Strany 13 - CUSTOMER

Page 20 AEGIS THERMOSTATS Aegis 1000 supports up to 2 Aegis Communicating Thermostats. The controller can send commands to the thermostat to chan

Strany 14

Page 21 PROGRAMMABLE ENERGY SAVER MODULES Programmable Energy Saver Modules may be connected to: Controller: Zone 7 and Output 1 and/or Zone 8 a

Strany 15

Page 22 4. Heat Pumps Programmable Energy Saver Modules are compatible with heat pumps, however, the savings gained by setting the heat pump back

Strany 16 - BOTTOM PLATE

Page 23 HEAT /AIRSYSTEMBLACKREDYELLOWGREENPROGRAMMABLE ENERGYSAVER MODULERED LEDON - ENERGY SAVER ISOVERRIDING THERMOSTATOFF - THERMOSTAT ISWORKING

Strany 17 - BELL OUTPUT

Page 24 BUILT-IN SERIAL INTERFACE Aegis 1000 has a serial interface built onto the controller (designated as J5 SERIAL). The interface is a modul

Strany 18

Page 25 SYSTEM POWER UP PROCEDURE 1. Carefully review connections to the zones, grounds, sounders, and consoles. 2. Disconnect the sounders.

Strany 19 - REMOTE ARM/DISARM SWITCH

Page 26 5. Record the owner's NAME and ADDRESS in the ADDRESS speech memory as shown in SETUP ADDRESS in the OWNER'S MANUAL (Press 8, 9,

Strany 20 - AEGIS THERMOSTATS

Page 27 You should also: 4. Demonstrate arming and disarming. 5. Demonstrate home control. 6. Demonstrate setup and programming. 7. Deliver the

Strany 21

Page 28 8. Call HSP (800-401-4663) with the serial number for a return authorization number. Write the RA# on the outside of the package. 9. Retu

Strany 22

Page 29 DIGITAL COMMUNICATOR The Aegis 1000 digital communicator can use Contact ID, or Standard 4/2 or 3/1, (20 pps, 1800 Hz data, 2300 Hz handsh

Strany 23 - SAVER MODULE

CONTENTS INTRODUCTION...5 INSTALLATION...5 CONTROLLER HOOKUP

Strany 24 - RS-232 CONNECTIONS

Page 30 3/1 FORMAT Older central stations may require a 3/1 format. To use 3/1 format, both account numbers must be changed to 3 digit codes and

Strany 25 - SYSTEM POWER UP PROCEDURE

Page 31 INSTALLER SETUP This section describes the items that the installer must setup as part of system installation. The Installer Setup mode i

Strany 26

Page 32 OUTPUT TYPE NUMBER DESCRIPTION GENERAL PURPOSE 0 General Purpose Output OK TO ARM 1 OK To Arm ARMED 2 Armed PRE-ALM SNDR

Strany 27 - IN CASE OF TROUBLE

Page 33 The current Zone Type setting is shown on the bottom line. To change a zone type, use the arrow keys to scroll through the list of zone ty

Strany 28 - X-10 TROUBLESHOOTING TIPS

Page 34 There are two special types of ENTRY/EXIT ZONES for use with garage doors, or doors that are far away from the control console. They are c

Strany 29 - DIGITAL COMMUNICATOR

Page 35 FIRE EMERGENCY This zone type activates the fire alarm for a normally closed (open for alarm) and open collector (short to ground for ala

Strany 30

Page 36 TEMPERATURE The general-purpose TEMPERATURE ZONE type is typically used to monitor indoor temperatures and control devices. It sets the

Strany 31 - INSTALLER SETUP

Page 37 COMMUNICATOR TYPE This item is used to select the transmitting parameters of the digital communicator. The Aegis 1000 can transmit in FAS

Strany 32

Page 38 To disable the digital communicator for a specific zone, set the alarm code to 0 or 00. The digital dialer will not report when this zone

Strany 33

Page 39 NOTE: Remember this Installer code and do not disable. There is no way to reset or retrieve the code! If the code is forgotten or disab

Strany 34

SMOKE DETECTOR INSTALLATION GUIDELINES...46 APPENDIX A – CONTACT ID REPORTING FORMAT...

Strany 35

Page 40 To change the alarm reset time, enter a new time between 1-30 minutes, then press the ' # ' key. The default setting is 4 minut

Strany 36

Page 41 TIME DISPLAY This allows you to choose between AM/PM or 24 HOUR time format. TIME DISPLAY: 1 1=AM/PM 2=24HR × DAT

Strany 37

Page 42 MODEL AND SOFTWARE VERSION The model number and software version for the system is displayed: AEGIS 1000 S/W VERSION 2.0 ×

Strany 38

Page 43 MODULE 2 TYPE - MODULE 4 TYPE Module 2 is the module with the jumper set to 2, and so on. Set each module type from the list above. SERI

Strany 39

Page 44 AEGIS 1000 SPECIFICATIONS Size: Controller: 9.1 W x 12.1 H x 3.5 D Console: 4.6 W x 4.5 H x 1.2 D Weight: Controller: appr

Strany 40

Page 45 UNDERWRITER'S LABORATORIES (UL) INSTALLATION REQUIREMENTS The Aegis 1000 control unit (21A00-14) is suitable for Grade A household bur

Strany 41

Page 46 SMOKE DETECTOR INSTALLATION GUIDELINES 1. Ceiling mounted smoke detectors should be located in the center of the room or hall, or not less

Strany 42

Page 47 APPENDIX A – CONTACT ID REPORTING FORMAT ZONE TYPE TRIP TROUBLE DESCRIPTION Entry/exit (also Double & Quad) 134 370 Entry

Strany 45 - Page 45

Page 5 INTRODUCTION This installation guide is intended as an aid to installing the Aegis 1000 automation system. The installer should also have

Strany 46

800-401-HOME (4663) www.Aegishome.com

Strany 47

Page 6 RED WIRE TO +BLACK WIRE TO -TWO - WAYPOWER LINE INTERFACE4 CONDUCTORBATTERY12V 7AHCOLD WATER PIPEOR GROUND RODGOUNDING METHOD MUST BE INA

Strany 48

Page 7 ABOUT SECURITY ZONES Zones 1-8 on the controller and zones 9-24 on the expander may be configured as security zones, fire zones, temperatur

Strany 49

8 EARTHGROUNDTRANSFORMER16.5VAC 40VAAUXILIARY12VDCSOUNDERCONSOLE(S) ZONEINPUT INPUTZONE REMOTECONTROLTHERMOSTAT(S)OUTPUTOUTPUTCONNECT CABLETO CO

Strany 50 - 800-401-HOME (4663)

Page 9 ABOUT FIRE ZONES The Aegis 1000 system supports normally open (closed for alarm), two- -wire smoke detectors. Two wire smoke detectors can o

Komentáře k této Příručce

Žádné komentáře